Main menu

Human saliva DNA


Introduction

This protocol describes a method to extract high molecular weight genomic DNA from human saliva. The saliva was pooled from multiple individuals to account for variability among samples, and stored in an Isohelix GeneFiX™ Saliva DNA Collection Device. The extraction was carried out using the QIAGEN Blood and Cell Culture DNA Midi Kit followed by size selection with the Size selection of HMW DNA by semi-selective DNA precipitation protocol. Sequencing performance was assessed using the MinION.

Materials

Method

  1. Collect 1 ml of saliva and store it at room temperature in an Isohelix GeneFiX™ Saliva DNA Collection Device until ready to extract the DNA.

  2. Transfer 1 ml of saliva to a 15 ml Falcon tube and add 19 µl of RNase A.

  3. Add 5 ml of Buffer G2 and 95 µl of Proteinase K to the tube, and mix by inverting the tube.

  4. Incubate the tube for 15 minutes at 37°C, and then for 1 hour at 50°C.

  5. Equilibrate a QIAGEN Genomic-tip 100/G column with 4 ml of Buffer QBT.

  6. Pour the lysate through the column.

  7. Purify the lysate according to the standard protocol (steps 3–6, pages 50–52).

  8. To maximize DNA yield, we recommend that the elution is performed overnight at room temperature in 150 µl TE buffer.

  9. Take 3 µg of extracted DNA and perform a Size selection of HMW DNA by semi-selective DNA precipitation. The expected DNA recovery after size selection is ~40–50%.

Results

  • Yield: 6-12 µg
  • OD 260-280: 2.01
  • OD 260/230: 2.61

saliva

Sequencing performance

Libraries were prepared using the Ligation Sequencing Kit.

  • Read length profile:

2019 08 01 Saliva read length

Change log

Version Change
v2, September 2021 Updated protocol to size select DNA using the size selection of HMW DNA by semi-selective DNA precipitation protocol
Oxford Nanopore Technologies, the Wheel icon, AmPORE-TB, EPI2ME, GridION, MinION, MinKNOW, PromethION, P2 Solo, and P2 are registered trademarks or the subject of trademark applications of Oxford Nanopore Technologies plc in various countries. Information contained herein may be protected by copyright, patents or patents pending of Oxford Nanopore Technologies plc. All other brands and names contained are the property of their respective owners. Oxford Nanopore Technologies products are RUO. Products labelled/branded as Oxford Nanopore Diagnostics may be RUO or may be regulated as in‐vitro diagnostic devices in some jurisdictions, please check individual product labelling. ONT plc is a member of the producer compliance scheme run by ERP UK Ltd, who manage the submission of documentation in support of WEEE compliance for ONT plc’s manufacture and supply of Electrical and Electronic equipment in the UK. ONT’s WEEE PRN is WEE/MM3828AA.

Last updated: 4/10/2026