Direct-from-colony rapid microbial sequencing for Salmonella serotyping using SQK-RPB114.24 (DCM_9210_V114_revG_28Apr2026)


DateVersionLanguageDeviceChanges
4/28/2026DCM_9210_V114_revG_28Apr2026EnglishGridION
28th April 2026 - In section 1, 'Compatibility of this protocol', the links for the sequencing devices were updated.
4/28/2026DCM_9210_V114_revG_28Apr2026EnglishMinION
28th April 2026 - In section 1, 'Compatibility of this protocol', the links for the sequencing devices were updated.
4/28/2026DCM_9210_V114_revG_28Apr2026EnglishGridION
28th April 2026 - In section 1, 'Compatibility of this protocol', the links for the sequencing devices were updated.
4/28/2026DCM_9210_V114_revG_28Apr2026EnglishMinION
28th April 2026 - In section 1, 'Compatibility of this protocol', the links for the sequencing devices were updated.
11/11/2025DCM_9210_V114_revF_11Nov2025EnglishGridION
11th November 2025 - In section 1, in the Table under 'Library preparation', the timing for the priming and loading a flow cell was increased from 5 min to 10 min. And in 'Compatibility of this protocol', MinION Mk1B was removed, along with its link for IT requirements as this device document has moved to legacy. - In section 3, 'Library preparation', a note was added to check your flow cell and to use the barcode wells only once. - In section 4, 'Priming and loading the MinION/GridION Flow Cell', a tip was added to bring the flow cell to room temperature for better visibility of the array. The addition of BSA to the flow cell priming mix was changed from a 'recommended' to a 'required' instruction. A note was added to the end of this section to explain that when a flow cell is inserted into the MinION Mk1D, there will be a small gap around the sides of the device. - Links in section 6, 'Downstream analysis' were updated.
11/11/2025DCM_9210_V114_revF_11Nov2025EnglishMinION
11th November 2025 - In section 1, in the Table under 'Library preparation', the timing for the priming and loading a flow cell was increased from 5 min to 10 min. And in 'Compatibility of this protocol', MinION Mk1B was removed, along with its link for IT requirements as this device document has moved to legacy. - In section 3, 'Library preparation', a note was added to check your flow cell and to use the barcode wells only once. - In section 4, 'Priming and loading the MinION/GridION Flow Cell', a tip was added to bring the flow cell to room temperature for better visibility of the array. The addition of BSA to the flow cell priming mix was changed from a 'recommended' to a 'required' instruction. A note was added to the end of this section to explain that when a flow cell is inserted into the MinION Mk1D, there will be a small gap around the sides of the device. - Links in section 6, 'Downstream analysis' were updated.
5/9/2025DCM_9210_V114_revE_09May2025EnglishGridION
09th May 2025 - Added information for SQK-RPB114.24 kit format update from vials to plate. - Included instructions for both kit formats: old vial format with Rapid Barcode Primers at 10 μM, new plate format with Rapid Barcode Primers at 1 μM. - Protocol title update
5/9/2025DCM_9210_V114_revE_09May2025EnglishMinION
09th May 2025 - Added information for SQK-RPB114.24 kit format update from vials to plate. - Included instructions for both kit formats: old vial format with Rapid Barcode Primers at 10 μM, new plate format with Rapid Barcode Primers at 1 μM. - Protocol title update
12/11/2024DCM_9210_V114_revC_11Dec2024EnglishGridION
11th December 2024 - Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol". - Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell. - Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells. - Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/11/2024DCM_9210_V114_revC_11Dec2024EnglishMinION
11th December 2024 - Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol". - Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell. - Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells. - Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
9/30/2024DCM_9210_V114_revB_30Sep2024EnglishGridION
30th September 2024 - Included biosafety warning for pathogenic organisms and recommendation to use appropriate laboratory equipment to protocol introduction. - Incuded biosafety warnings in the preparation method. - Included recommendations to protocol introduction for sample storage following PCR amplification. - Updated PCR step to include EDTA quench reaction following amplification.
9/30/2024DCM_9210_V114_revB_30Sep2024EnglishMinION
30th September 2024 - Included biosafety warning for pathogenic organisms and recommendation to use appropriate laboratory equipment to protocol introduction. - Incuded biosafety warnings in the preparation method. - Included recommendations to protocol introduction for sample storage following PCR amplification. - Updated PCR step to include EDTA quench reaction following amplification.
9/4/2024DCM_9210_V114_revA_04Sep2024EnglishGridION
04th September 2024 Protocol release
9/4/2024DCM_9210_V114_revA_04Sep2024EnglishMinION
04th September 2024 Protocol release