Ficha técnica GridION mk1
- Home
- Documentation
- Ficha técnica GridION mk1
Requirements
Ficha técnica GridION mk1
FOR RESEARCH USE ONLY
Contents
Device part number
Device name
Short description
Product overview
Safety and legal information
- 4. Intended use of the GridION Mk1 device
- 5. Electrical information
- 6. Labels on the instrument
- 7. Emergency procedures
- 8. Declaration of conformity
License and Warranty
What’s in the box
Product cross-compatibility
Change log
Device part number
GRD-MK1 or GRD-X5B003
Device name
GridION Mk1
Short description
GridION Mk1 is a cost-effective and compact benchtop system offering on-demand sequencing with integrated real-time data processing. With the capacity to run five flow cells either concurrently or individually and a total yield of up to 150 Gb, GridION Mk1 provides busy labs and service providers with cost-efficient access to the advantages of long-read, real-time nanopore sequencing. Integrated, high-performance data processing alleviates the need for complex IT infrastructure.
Product overview
The Oxford Nanopore Technologies® GridION™ Mk1 is a compact benchtop sequencing system. It allows up to five sequencing experiments to be run concurrently or individually. You may choose to use as much or as little of this total resource at any one time. GridION Mk1 also allows you to offer nanopore sequencing as a service.
The GridION Mk1 has five sequencing ports where MinION/GridION Flow Cells or Flongle Adapters with flow cells can be connected, as well as a high performance integrated computer and basecalling accelerator. The device can basecall, in real-time, the data generated by five flow cells/Flongles. The current chemistry and software enables generation of up to 150 Gbases of data during a GridION Mk1 run.
Setting up a GridION Mk1 requires minimal infrastructure with no need for facility upgrades. A new device requires only a power source, and network connectivity via an Ethernet port.
There are three USB 3.0 ports available for peripherals, e.g. keyboard and mouse. Monitors must be connected via DisplayPort.
The device is powered from the mains via the C13 cable, and is switched on via a power button on the front.
Technical specifications
Component | Specification |
---|---|
Size and weight | H 220 x W 365 x D 370 mm, 14.4 kg |
Compute spec | 7 TB SSD storage*, 64 GB RAM, Intel i7-10700K CPU for OS and orchestration, basecalling accelerator |
Pre-loaded software | Linux OS, GridION OS (MinKNOW inside) |
Environmental conditions | System functional range +5°C to +40°C Designed to sequence at +18°C to +25°C |
Important: *GRD-MK1 devices with serial numbers below GXB05000 have 4 TB SSD storage.
Shipping and logistics
The Oxford Nanopore Technologies GridION Mk1 device is stored and shipped at ambient temperature (+15°C to +25°C).
Please note that the GridION Mk1 is shipped separately to the kits and flow cells.
The delivery charge of $2000 is included in the package price. Additional delivery charges for the consumables are calculated when a quote is raised or during checkout. Once an order is made, the delivery ID and delivery information can be tracked in the Store.
IT requirements
Safety and legal information
Intended use of the GridION Mk1 device
Oxford Nanopore Technologies GridION Mk1 device is an electronic analysis system for use in scientific research. The core technology is built around a nanopore that is able to detect single molecule events such as nucleic acids (DNA/RNA).
This product is for research use only.
The safety information below provides you with the details needed to install and use the system safely.
Electrical information
Supply voltage | 100–240 V (50/60 Hz) |
Operating current | 6.5 A maximum |
Maximum power | 650 W |
Labels on the instrument
Label on the GridION Mk1:
Label on the MinION/GridION Flow Cell:
Emergency procedures
In case of emergency, switch the GridION Mk1 off at the power switch and unplug the power cable from the back of the device.
Declaration of conformity
The GridION conforms to the EMC and Electrical Safety directives as outlined in the EC Declaration of Conformity.
License and Warranty
The license and warranty contract ensures your instrument is performing optimally by providing the latest up-to-date hardware and software. The contract guarantees that Oxford Nanopore Technologies support obligations are delivered during the contract period as laid out in sections 4 and 7 of the Nanopore Product Terms and Conditions.
For more information, see the Device Warranty page on the Oxford Nanopore Store.
What’s in the box
The GridION Mk1 is shipped together with a C13 cable specific to the country of delivery, five configuration test cells (CTCs), a HDMI adapter, a Quick Start Guide, and Safety and regulatory information.
Configuration is the process of testing that communication between the GridION Mk1 device and the control software is operational prior to experimental work being performed. This is carried out in the absence of any chemistry and uses a specific flow cell known as the Configuration Test Cell (CTC).
The GridION Mk1 is packed into a single box that contains everything needed for installing the device. The device weight is 14.4 kg, meaning no special equipment is required for installing the GridION Mk1 in your laboratory.
Product cross-compatibility
The GridION Mk1 can be used together with:
Flow cells
- MinION/GridION Flow Cell (FLO-MIN114)
- MinION/GridION Flow Cell – RNA (FLO-MIN004RA)
- Flongle Flow Cell (FLO-FLG114)
Kits
- Ligation Sequencing Kit V14 (SQK-LSK114)
- Ligation Sequencing Kit XL V14 (SQK-LSK114-XL)
- Ultra-Long DNA Sequencing Kit V14 (SQK-ULK114)
- Multiplex Ligation Sequencing Kit XL V14 (SQK-MLK114.96-XL)
- Rapid Sequencing Kit V14 (SQK-RAD114)
- Rapid Barcoding Kit 24 V14 (SQK-RBK114.24)
- Rapid Barcoding Kit 96 V14 (SQK-RBK114.96)
- Rapid PCR Barcoding Kit 24 V14 (SQK-RPB114.24)
- Native Barcoding Kit 24 V14 (SQK-NBD114.24)
- Native Barcoding Kit 96 V14 (SQK-NBD114.96)
- 16S Barcoding Kit 24 V14 (SQK-16S114.24)
- cDNA-PCR Sequencing Kit V14 (SQK-PCS114)
- cDNA-PCR Barcoding Kit V14 (SQK-PCB114.24)
- Direct RNA Sequencing Kit (SQK-RNA004)
Software Basecalling:
- MinKNOW
- Dorado
Basecalled reads are available as POD5, FASTQ, and BAM files.
Downstream analysis:
- EPI2ME
- Oxford Nanopore-developed tools and pipelines
- Customer-developed tools and pipelines
Change log
Date | Version | Changes made |
---|---|---|
13th November 2024 | V10 | - In "Technical specifications", GRD-MK1 devices with serial numbers below GXB05000 having a 4 TB SSD storage was added. - In "Shipping and logistics", the ambient temperature of (+15–25°C) was changed for clarity to (+15°C to +25°C). - In "License and Warranty", the link to the device warranty was updated. - In "What's in the box", a Quick Start Guide, and Safety and regulatory information were added. - In "Product cross-compatibility", under "Software", availability of basecalled reads as BAM files was added. |
24th April 2024 | V9 | - In "Technical specifications", made corrections to the computer spec - Made corrections to "Electrical information" - Added HDMI adapter to "What's in the box", and corrected the device weight - Updated the License and Warranty information - Updated the Declaration of Conformity |
26th February 2024 | V8 | - Minor corrections and clarifications throughout the document - List of product cross-compatibilities has been updated |
March 2023 | V7 | In "Technical specifications", the compute spec has been updated to Intel i7-10700K CPU. |
January 2023 | V6 | Update to the EC Declaration of Conformity document |
May 2022 | V5 | - Updates to the device part numbers (now both GRD-MK1 and GRD-X5B003 are available) - The functional temperature range for electronics has been updated to +5°C–+40°C |
Feb 2022 | V4 | - Updates to the device part number, product overview and illustration of device components and ports - Updates to kit and flow cell compatibilities |
Nov 2020 | V3 | - Updates to kit compatibilities |
Feb 2020 | V2 | - Updates to the CE label and Declaration of Conformity - Updated product cross-compatibility list |