Main menu

Ligation sequencing DNA V14 - automated Tecan DreamPrep NGS (SQK-LSK114-XL) (DTD_9181_v114_revL_02Oct2025)


DateVersionLanguageDeviceChanges
10/2/2025DTD_9181_v114_revL_02Oct2025EnglishGridION
2nd October 2025 - In 'Overview of the protocol', an important note on Kit14 sequencing and duplex basecalling info sheet was removed as this is a Legacy document and its information is no longer applicable. - In 'Compatibility of this protocol', MinION Mk1B and Mk1C were replaced with Mk1D as these device documents have moved to legacy and their user manuals were removed from 'Data acquisition and basecalling'. - - In 'Priming and loading the MinION/GridION Flow Cell', a tip was added to bring the flow cell to room temperature for better visibility of the array. And the addition of BSA to the flow cell priming mix was changed from a 'recommended' to a 'required' instruction. In 'Complete a flow cell check', the link for the flow cell check in MinKNOW was replaced with the flow cell check document. And an important note regarding the MinION Mk1D device leaving a small gap around the sides, when a flow cell is inserted and the lid is closed was added to the end of this section. - In 'Priming and loading the PromethION Flow Cell', the step to remove the flow cell from the fridge was moved to the top of this section and a step to complete a flow cell check was included. - In 'Data acquisition and basecalling' information on duplex basecalling was removed as it is no longer applicable.
10/2/2025DTD_9181_v114_revL_02Oct2025EnglishMinION
2nd October 2025 - In 'Overview of the protocol', an important note on Kit14 sequencing and duplex basecalling info sheet was removed as this is a Legacy document and its information is no longer applicable. - In 'Compatibility of this protocol', MinION Mk1B and Mk1C were replaced with Mk1D as these device documents have moved to legacy and their user manuals were removed from 'Data acquisition and basecalling'. - - In 'Priming and loading the MinION/GridION Flow Cell', a tip was added to bring the flow cell to room temperature for better visibility of the array. And the addition of BSA to the flow cell priming mix was changed from a 'recommended' to a 'required' instruction. In 'Complete a flow cell check', the link for the flow cell check in MinKNOW was replaced with the flow cell check document. And an important note regarding the MinION Mk1D device leaving a small gap around the sides, when a flow cell is inserted and the lid is closed was added to the end of this section. - In 'Priming and loading the PromethION Flow Cell', the step to remove the flow cell from the fridge was moved to the top of this section and a step to complete a flow cell check was included. - In 'Data acquisition and basecalling' information on duplex basecalling was removed as it is no longer applicable.
10/2/2025DTD_9181_v114_revL_02Oct2025EnglishPromethION
2nd October 2025 - In 'Overview of the protocol', an important note on Kit14 sequencing and duplex basecalling info sheet was removed as this is a Legacy document and its information is no longer applicable. - In 'Compatibility of this protocol', MinION Mk1B and Mk1C were replaced with Mk1D as these device documents have moved to legacy and their user manuals were removed from 'Data acquisition and basecalling'. - - In 'Priming and loading the MinION/GridION Flow Cell', a tip was added to bring the flow cell to room temperature for better visibility of the array. And the addition of BSA to the flow cell priming mix was changed from a 'recommended' to a 'required' instruction. In 'Complete a flow cell check', the link for the flow cell check in MinKNOW was replaced with the flow cell check document. And an important note regarding the MinION Mk1D device leaving a small gap around the sides, when a flow cell is inserted and the lid is closed was added to the end of this section. - In 'Priming and loading the PromethION Flow Cell', the step to remove the flow cell from the fridge was moved to the top of this section and a step to complete a flow cell check was included. - In 'Data acquisition and basecalling' information on duplex basecalling was removed as it is no longer applicable.
10/4/2023DTD_9181_v114_revK_22Feb2023EnglishGridION
4th October 2023 - Updated the format of the final step in the "Adapter ligation and clean-up" step for the checklist
10/4/2023DTD_9181_v114_revK_22Feb2023EnglishMinION
4th October 2023 - Updated the format of the final step in the "Adapter ligation and clean-up" step for the checklist
10/4/2023DTD_9181_v114_revK_22Feb2023EnglishPromethION
4th October 2023 - Updated the format of the final step in the "Adapter ligation and clean-up" step for the checklist

入門

MinION Starter Packを購入 ナノポア製品の販売 シークエンスサービスプロバイダー グローバルディストリビューター

お問い合わせ

Intellectual property Cookie policy Corporate reporting Privacy policy Terms & conditions Accessibility

Oxford Nanoporeについて

Contact us 経営陣 メディアリソース & お問い合わせ先 投資家向け Oxford Nanopore社で働く BSI 27001 accreditationBSI 90001 accreditationBSI mark of trust
Japanese flag