From portable to high-throughput benchtop devices, real-time nanopore sensing is a new generation of technology uncovering new biology across multiple sectors.
31 July 2024
- Updated the protocol format to the new "slimmed-down" introduction sections.
- Updated workflow image in introduction to fix formatting errors in PDF generation
- Updated the Reverse transcriptase reagents and steps to the new method using Induro® Reverse Transcriptase (NEB, cat # M0681).
- Updated the RNase Inhibitor reagents and steps to the new method using Murine RNase Inhibitor (NEB, M0314).
- Updated first Agencourt RNAClean XP bead clean in Library Preparation section to elute into 23 ul Nuclease-free water, retain the full 23 ul and no longer have to add 3 ul of water in the next step.
- Updated "Flow cell reuse and returns" section to specify compatibility and use-cases for the Flow Cell Wash Kit with the RNA sequencing kit and RNA flow cells.
Jul 31 2024
DRCE_9196_v4_revB_20Sep2023
English
MinION
31 July 2024
- Updated the protocol format to the new "slimmed-down" introduction sections.
- Updated workflow image in introduction to fix formatting errors in PDF generation
- Updated the Reverse transcriptase reagents and steps to the new method using Induro® Reverse Transcriptase (NEB, cat # M0681).
- Updated the RNase Inhibitor reagents and steps to the new method using Murine RNase Inhibitor (NEB, M0314).
- Updated first Agencourt RNAClean XP bead clean in Library Preparation section to elute into 23 ul Nuclease-free water, retain the full 23 ul and no longer have to add 3 ul of water in the next step.
- Updated "Flow cell reuse and returns" section to specify compatibility and use-cases for the Flow Cell Wash Kit with the RNA sequencing kit and RNA flow cells.
Jul 31 2024
DRCE_9196_v4_revB_20Sep2023
English
PromethION
31 July 2024
- Updated the protocol format to the new "slimmed-down" introduction sections.
- Updated workflow image in introduction to fix formatting errors in PDF generation
- Updated the Reverse transcriptase reagents and steps to the new method using Induro® Reverse Transcriptase (NEB, cat # M0681).
- Updated the RNase Inhibitor reagents and steps to the new method using Murine RNase Inhibitor (NEB, M0314).
- Updated first Agencourt RNAClean XP bead clean in Library Preparation section to elute into 23 ul Nuclease-free water, retain the full 23 ul and no longer have to add 3 ul of water in the next step.
- Updated "Flow cell reuse and returns" section to specify compatibility and use-cases for the Flow Cell Wash Kit with the RNA sequencing kit and RNA flow cells.